Promise Technology J310S, J610S manual Help Command, Making Settings

Models: J610S J310S

1 62
Download 62 pages 43.72 Kb
Page 43
Image 43

Chapter 3: Management

Automatic Shutdown – Shuts down the VTrak 30 seconds after the enclosure or controller reaches critical temperature.

Minimum Fan Speed – Specifies the minimum fan speed when the VTrak reaches enclosure or controller warning temperature.

Making Settings

To set the enclosure critical temperature to 61°C (141°F):

cli>enclosure -a mod -s “enc_critical=61”

To enable Thermal Management:

cli>enclosure -a mod -s “thermalmanager=1”

For this command, a 1 enables and a 0 disables.

To enable Automatic Shutdown:

cli>enclosure -a mod -s “allowshutdown=1”

For this command, a 1 enables and a 0 disables.

To set the minimum fan speed to medium high:

cli>enclosure -a mod -s “minfanspeed=3”

For this command:

1 means low

2 means medium-low

3 means medium-high

4 means high

The actual speed depends on the fan manufacturer.

To display a complete list of Enclosure commands:

cli>enclosure -h

Help Command

The VTrak CLI uses the standard Unix online help system.

To access general help:

cli>help

39