Installation and Operating Instructions

Owner’s Reference PowerPlay 8500

UPS Priority

When PowerPlay is connected to a PS Audio PowerPack battery backup you may control how each outlet shuts down in a battery backup

situation.

Using the drop box you may select one of the following options:

Low – No battery backup is provided to these outlets in order to quickly reduce the load and extend battery life. Use this setting for amps,

subwoofers and other large draw devices.

Normal – Some battery protection is provided, but outlets turn off when UPS reaches 25% battery remaining. Use this setting to safely shut down devices such as projectors or any other device which require some user interaction to properly shut down.

Critical – Full battery protection, outlets remain powered until battery runs out. Use this setting for network critical or other devices which need to

remain powered as long as possible.

Important: All battery backup devices, including the PowerPack, are limited in load capabilities. Reducing the load quickly will greatly extend

the battery backup time.

Important: Changes made in the configuration tab must be confirmed by clicking on the Submit Changes button at the

top of the page.