6-114 0DJHOODQ 6FDQQHU
83&$1XPEHU6\VWHP&KDUDFWHU7UDQVPLVVLRQ
Enables/disables transmission of a UPC-A number system character.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to
cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
UPC-A NUMBER SYSTEM CHARACTER TRANSMISSION = DI SABLE
UPC-A NUMBER SYSTEM CHARACTER TRANSMISSION = ENABLE
NOTE
This feature MUST be enabled for IBM interfaces for proper function.
This item is ignored when the advanced feature, Full Label Edit, is enabled.