Quadra-Fire CASTILE-MBK, CASTILE-CLG A. Mobile Home Installation, Castile Pellet Stove

Models: CASTILE-CCR CASTILE-PMH CASTILE-CLG CASTILE-MBK

1 44
Download 44 pages 30.22 Kb
Page 16
Image 16
Mobile Home

 

R

Castile Pellet Stove

 

 

 

 

 

 

 

 

 

6

Mobile Home

 

 

 

 

 

A. Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for installation in a mobile home.

1.An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smoke spillage. Smoke spillage can also set off smoke alarms.

2.The combustion air duct system must be made of metal. It must permit zero clearance to combustible construction and prevent material from dropping into the inlet or into the area beneath the dwelling and contain a rodent screen.

3.The appliance must be secured to the mobile home structure by bolting it to the floor (using lag bolts). Use the same holes that secured the appliance to the shipping pallet.

4.The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device.

5.Refer to clearances to combustibles and floor protection requirements on pages 8 & 9 for listings to combus- tibles and appropriate chimney systems.

6.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure.

7.Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home.

8.Installation shall be in accordance with the Manufactur- ers Home & Safety Standard (HUD) CFR 3280, Part 24.

A. Mobile Home Installation WARNING

Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

CAUTION

Maintain structural integrity of mobile home:

Floor, wall, ceiling and/or roof. Do NOT cut through:

Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integrity.

CAUTION

Never draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

 

Spark Arrestor Cap

Storm Collar

 

 

Roof Flashing

Joist Shield/Firestop

Double Wall

 

 

Pellet Vent

Figure 16.1

Manual background WARNING

Never install in a sleeping room.

Page 16

250-6422D

October 11, 2005

Page 16
Image 16
Quadra-Fire CASTILE-MBK, CASTILE-CLG, CASTILE-CCR, CASTILE-PMH A. Mobile Home Installation, Castile Pellet Stove

FAQ

What are the installation requirements for a mobile home?

You must use a Quadra-Fire Outside Air Kit, provide an outside air inlet, use a metal combustion air duct system, secure the appliance to the mobile home structure, ground the appliance, and follow chimney manufacturer's instructions for vent system installation.

How should I maintain the structural integrity of my mobile home during installation?

Do not cut through floor joists, wall studs, or ceiling trusses, and never draw outside combustion air from enclosed spaces such as an attic or garage.

Can I install the pellet stove in a sleeping room?

No, it is warned to never install the pellet stove in a sleeping room.