R

Castile Pellet Stove

 

 

 

 

 

 

 

 

 

1 Listing and Code Approvals

 

 

 

 

 

 

A. Appliance Certification

Model:

Castile Pellet Stove

Laboratory:

OMNI Test Laboratories, Inc.

Report No.

061-S-33-2

Type:

Solid Fuel Room Heater/Pellet Type

Standard:

ASTM E1509 and ULC/ORD-C1482

 

Room Heater Pellet Fuel Burning

 

type and (UM) 84-HUD, Mobile Home

 

Approved.

State Listing:

State of Colorado

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only listed pellet vent Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the

ASTM E1509, (UM) 84-HUD, ULC/ORD-C-1482

E. BTU & Efficiency Specifications

Particulate Emis-

.7 grams/hr

sions Rating:

 

*BTU Output:

8,000 - 30,000 / hr

Heating Capacity:

up to 1,500 sq. ft.

Hopper Capacity:

40 lbs

Fuel:

Wood Pellets or Shelled Corn

Shipping Weight:

258 lbs

*BTU output will vary, depending on the brand of fuel you use in your stove. Consult your Quadra-Fire dealer for best results.

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

D. Electrical Rating

115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps

Page 4

250-6422D

October 11, 2005