C. Hearth Pad Requirements (UL and ULC)

Use a noncombustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door.

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

*L Exception for Horizontal Installations:

USA INSTALLATIONS: A noncombustible floor protection is recommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation.

CANADA INSTALLATIONS: A noncombustible floor pro- tection extending beneath the flue pipe is required with hori- zontal venting or under the Top Vent Adapter with vertical installation.

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)