Quadra-Fire QFP38-NG D. Mantel and Wall Projections, Mantels, Mantel Legs or Wall Projections

Models: QFP38-NG QFP38-LP

1 76
Download 76 pages 45.19 Kb
Page 30
Image 30

D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of non-combustible materials (i.e., steel studs, concrete board, etc).

Mantels

30 in. minimum

to ceiling

12

11

0 - 10

23

22 1/2

22

Measured from appliance opening (in inches)

Figure 5.3 Clearances to Mantels or Other Combustibles above Appliance

Mantel Legs or Wall Projections

Top of

ApplianceDrywall

A

B

Mantel Leg or

Perpendicular Wall

A5 in. (127 mm) Min. to perpendicular wall

B6 in. (152 mm) Min. from fireplace opening to perpendicular wall

Figure 5.4 Mantel Leg or Wall Projections (Acceptable on both sides of opening)