Quadra-Fire QFP38-LP, QFP38-NG owner manual I. Install Horizontal Termination Cap

Models: QFP38-NG QFP38-LP

1 76
Download 76 pages 45.19 Kb
Page 47
Image 47

I. Install Horizontal Termination Cap

WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent.

1-1/2 (38 mm) minimum overlap of flue telescoping section is required.

Failure to maintain overlap may cause overheating and fire.

Vent termination must not be recessed in the wall. Siding may be brought to the edge of the cap base.

Flash and seal as appropriate for siding material at outside edges of cap.

When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149installation codes and refer to Section 6 of this manual.

CAUTION! Risk of Burns! Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.

NOTICE: For certain exposures which require superior resistance to wind-driven rain penetration, a flashing kit and HPC caps are available. When penetrating a brick wall, a brick extension kit is available for framing the brick.

Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall.

Heat Shield or

Heat Shield

Extended

1-1/2 in. (38 mm) min.

Wall Shield Heat Shield

overlap

Firestop

 

Slip Section

 

can be extended

 

Inner Vent

SHEATHING

Outer Vent

INTERIOR

EXTERIOR

Figure 10.16 Venting through the wall

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

47

Page 47
Image 47
Quadra-Fire QFP38-LP, QFP38-NG owner manual I. Install Horizontal Termination Cap