D. Junction Box Installation

Remove junction box from outer shell.

Remove front cover from junction box.

Knock out hole in junction box back and install Romex connector.

Feed necessary length of wire through connector.

Make all wire connections to receptacle as shown in Figure 13.4.

Reassemble jumction box with receptacle inside.

Insert junction box and receptable assembly through hole in outer shell (see Figure 13.3) and fasten with two screws.

Figure 13.3 Remove Junction Box Assembly

14-2 with ground Romex is the recommended wiring to the appliance junction box.

14-2 with

Ground Romex

BLACK

WHITE

GROUND

Figure 13.4 Junction Box Detail

E. Heat-Zone-Gas

Install the Heat Zone Kit before enclosing the appliance.

Remove one of two square cover plates for each kit from the top of the appliance. Set the screws aside, discard the cover plate.

Cover Plates

Figure 13.5 Cover Plates

Replace the cover plate with the heat zone collar from the kit. Use the three screws removed from the cover plate.

Return to Heat-Zone-Gas instructions.

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09