Quadra-Fire QVI-30FB To service or clean, Junction box installation, Serving the blower

Models: QVI-30FB

1 25
Download 25 pages 38.78 Kb
Page 18
Image 18
To service or clean:

 

INSERT STRAIN RELIEF

To service or clean:

 

 

• Remove the ground wire of the fan can clip on the side of

 

AROUND CORD IN THIS END

 

FROM OUTSIDE OF UNIT

the base pan.

 

 

FEED PLUG

 

 

 

THROUGH HOLE

SIDEWALL

• Remove the blower in between the bend up tabs.

 

 

 

 

 

• Install and wire the blower per instruction shipped with

 

 

the fan.

 

 

 

 

• Reinstall the blower in reverse order. Make sure the fan

 

 

does not make contact with the back wall.

JUNCTION

 

 

 

 

BOX

 

 

 

 

Figure 9.

SCREW

 

 

 

PROVIDED

 

 

 

Junction box installation

 

FAN

COVER

 

 

 

 

 

 

 

PLATE

Serving the blower

 

 

 

On units already installed removal of decorative front, sur-

 

 

 

round and gas insert is required.

 

 

 

• Detach flexible liner from the top of unit.

 

 

 

• Remove the four screws on the coverplate (see Figure 11).

Figure 11.

GROUND

 

• Bend up the tabs on the base pan (see Figure 10).

WIRE

 

 

 

 

 

VARIABLE SPEED CONTROL

REMOTE

 

 

 

RECEPTACLE

 

 

 

JUNCTION BOX

 

BLK

BLK

 

 

 

 

BLK

 

 

 

BLK

BLK

 

 

BLK

BLK

 

 

 

 

WHT

WHT

 

BLK

 

 

GROUND

 

TEMPERATURE

 

 

SENSOR SWITCH

GRN

 

 

BLK

WHT

 

110-120 VAC

 

 

 

FAN

NOTE: IF ANY OF THE ORIGINAL WIRE AS SUP- PLIED WITH THE APPLIANCE MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE 1050 C RATED WIRE.

Figure 10. Fan Wiring Diagram

BEND UP

TABS

BLOWER RECEPTACLE

BLOWER

REMOTE

 

OUTLET

JUNCTION

 

BOX

 

FAN

 

OUTLET

TEMPERATURE

SENSOR SWITCH

SPEED CONTROL

(RHEOSTAT)

GROUND WIRE

(ATTACH TO ANY METAL SURFACE)

18

Quadra-FireQVI-30FB2020-900 Rev. H • 9/07

Page 18
Image 18
Quadra-Fire QVI-30FB owner manual To service or clean, Junction box installation, Serving the blower, Fan Wiring Diagram