URC1 Control Codes:

The codes on the URC1 are very simple to use as well as comprehensive. Codes have been laid out so that the letters on a touch tone phone represent the action that you desire. Note that all codes begin with an asterisk. This was done to prevent the normal dialing of a phone or some other device from accessing the unit.

[ ] indicates not required or variable length. { } indicates one character

To access the URC1:

For master access: *M[Password]* or *6[Password]* Where master password length is at most 4 characters. This code replies with two long tones indicating “M”

For user access: *U[Password]* or *8[Password]* Where user password length is at most 3 characters.

This code replies with two shorts and a Long to indicate “U”

Ex:*M123*

Note that if no password has been set for either, the last asterisk is left off.

To set the password:

To set the master password: *PM[Password]* or *76[Password]* Where maximum password length is 4 characters. Entering no characters for password disables the password.

This code replies with a short then long tone to indicate “A” for acknowledge.

To set the user password: *PU[Password]* or *78[Password]* Where maximum password length is 3 characters. Entering no characters for password disables the password.

This code replies with a short then long tone to indicate “A” for acknowledge.

Note that you must be entered as a master to change these.

To set an output on or off:

To turn an output on:

*0{output set #}{Output #}1 or *6{output set #}{Output #}1 This code replies with a short then long tone to indicate “A” for acknowledge.