URC1 25
To set timer1 on for 35 hours 12seconds, and off fore 10mS:
*8101*00120035
Hook up some LEDs as shown with series resistors to the timer outputs, and
then experiment a bit to see how this method works. Have patience as these
codes take a little time to get used to.
For the master user to exclude devices from the user:
To exclude:
*X[00-18]1
To include:
*X[00-18]0
The access number is found on the chart with the pinouts of CON1. Since
there is only 19 devices (0-18), any number over 18 is rejected and the
command is aborted.
The URC1 replies with a short then long tone to indicate “A” for acknowledge.
Example to turn timer 2 off from the user:
*9181
Where 9 is the control code, 18 is the device number, and 1 disables the
device from the user changing it. Notice of course that you must be entered as
a master user to change these settings. Entering a 1 disables, and a 0
enables.
Special codes:
Resetting the entire unit:
Reset the display only:
*0000
Clear all:
*0CAL or *0252