5. How to install Windows 95/98

----------------------------- CBENABLE.EXE parameter --------------------------

Format: DEVICE = <directory path>: \ CBENABLE.EXE [IRQ] [IO] [MEM]

Parameter

[IRQ]

Set IRQ number used by the CB31U. If you don’t set anything to this parameter, Ah(10) is set as IRQ number. If this doesn’t work, you have to set IRQ number from among IRQ numbers which any devices don’t use. e.g.) IRQ = A

[IO]

Set IO port address used by the CB31U. If you don’t set anything to this parameter, 1300h is set as IO port address. If this doesn’t work, you have to set IO port address from among IO port address which any devices don’t use. e.g.) IO = 1000

[MEM]

Set memory address used by the CB31U. If you don’t set anything to this parameter, the CB31U try to assign memory address which any devices don’t use automatically. If the CB31U failed to assign memory address, memory address is not assigned. e.g.) MEM = CC00

MS-DOS

58