Raymarine FA-2E instruction manual Unpacking And Inspection

Models: FA-2E

1 23
Download 23 pages 50.34 Kb
Page 4
Image 4
2 UNPACKING AND INSPECTION

2 UNPACKING AND INSPECTION

Open the package and check that the product conforms to your order. Also check each of the following points. For any problem or inconsistency, contact Iwaki America at once.

1.Check that the model number indicated on the nameplate conforms to the specifications of your order.

2.Check that the pump body and parts have not been accidentally damaged or that any fasteners have not been loosened in transit.

Figure 1

Iwaki America F Series Air Driven Bellows Pumps consist of a high purity virgin fluoroplastic pump head assembly with dual bellows and internal valving. A bellows is affixed on each side of the pump head assembly which houses the suction and discharge valves. A connecting rod and shaft system are mounted to the bellows and structural air chambers which seal against the pump head assembly. The bellows move reciprocally in the air chambers as a result of alternating pressurization of the air chambers, by which liquid is pumped continuously. Position of each bellows is monitored by proximity sensors mounted in the air chambers. Signals from the proximity sensors are used by the controller system to govern the 4-way solenoid valve and subsequent pressurization of the pump air chambers.

2

Page 4
Image 4
Raymarine FA-2E instruction manual Unpacking And Inspection