Raymarine instruction manual 3.2Proximity Sensor Specifications for FA-2Epumps

Models: FA-2E

1 23
Download 23 pages 50.34 Kb
Page 7
Image 7
3.2Proximity Sensor Specifications (for FA-2E pumps)

3.2Proximity Sensor Specifications (for FA-2E pumps)

Type

Output system

Power source voltage

Current consumption

Setting distance

Hysteresis

Switching distance

Switching frequency

Output characteristics

Environmental temperature

Insulation voltage

Insulation resistance

Vibration resistance

Shock resistance

Protective construction

Case material

Cable

Connection

High frequency oscillation switch NPN DC open/close output

12-24 VDC ±10%, ripple (P-P): 10% max 13 mA max

Less than 80% of the switching distance 10% max of detecting distance 1.5mm (0.06 in) ±10%

800 Hz

Load current/100 mA max (+12/+24 VDC) Leakage current/less than 100 mA Residual voltage/less than 1.5V (1.0 V typ) -13°F to 176°F (-25°C to 80°C)

100 VAC 50/60 Hz 1 min. More than 50 mΩ

10-55 Hz, 1.5mm double amplitude

30G

IEC IP-67, NEMA type 6 SUS304

Oilproof vinychloride: length 6.56 ft (2m)

Diameter: 0.138 in (3.5mm)

 

 

 

Red

 

 

 

 

 

+12/+24 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

Sensor

 

 

 

 

 

 

 

 

 

Load

 

 

 

 

 

 

Black

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 