5.2.3 Air Piping

5.2.3 Air Piping

It is critical that all pneumatic piping and components be sized according to the porting of the pump. Full port components with matching effective cross-sectional area are recommended.

1.Effective cross-sectional area indicates the capacity to allow air to flow freely. When air is sent through a pipe, the air cannot run totally through the actual cross-sectional area of the pipe due to the negative effect of the piping resistance. The de facto cross-sectional area which serves the air flow is called the effective cross-sectional area. (The value increases as the capacity to allow air or fluid to flow freely increases.)

For the effective cross-sectional area value of the pneumatic device, refer to the manufacturer's catalog of each device.

2.Determination of composite effective cross-sectional area:

Air devices are connected in series with the pump. It is necessary to determine the composite effective cross-sectional area of the entire system from the sum of the cross-sectional areas of each device.

1

 

=

1

+

1

 

+

+

1

 

S2

 

(S2)2

(Sn)2

 

(S1)2

 

 

S =

 

Composite effective cross-sectional area for entire system

Si =

Effective cross-sectional area of each part

Effective cross-sectional area of air device/air pipe: See the catalog issued by each manufacturer.

Model

Composite effective cross-sectional area

FA-2

6.0 mm2

0.009 in2

FF-10

10.5 mm2

0.016 in2

FH-10

11.8 mm2

0.018 in2

FF-20, FF-40

13.2mm2

0.020 in2

FH-20, FZ-20

19.5mm2

0.030 in2

FA-40, FH-40

19.5mm2

0.030 in2

3.Diameter of pump connection port:

The diameter of the connection port on the air supply side is as follows:

Model

Pipe Thread Size

FA-2

1/8" PTF

FF-10, FH-10, FF-20

1/4" PTF

FH-20, FZ-20

3/8" PTF (FZ: NPTF)

FA-40, FF-40, FH-40

3/8" PTF

The inside diameter of the piping connectors and tubing should be larger than those of the pump connection port, if possible. Never install connectors or tubing with smaller diameters than the pump.