Raymarine FA-2E instruction manual Identification Codes, Specifications, FA - 2E - W02

Models: FA-2E

1 23
Download 23 pages 50.34 Kb
Page 6
Image 6
2 IDENTIFICATION CODES

2 IDENTIFICATION CODES

1 23

FA - 2E - W02

1.Series code: FA: Non-metallic pump for medium temperature liquid

2.Maximum discharge volume: 0.5 Gal/min (2L/min)

3.Special specifications

No symbol: Threaded suction & discharge

W02: Tubing connections

3 SPECIFICATIONS

3.1FA-2E Pump Specifications

Max. discharge volume Note 1

0.5 GAL/min

 

(2 L/min)

Max. stroke speed

150 spm

 

Max. stroke length

0.2 in

 

(5mm)

Self-priming ability Note 2

3 ft

 

(1m)

Liquid temp. range

41-212°F

 

(5-100°C)

Max. supply air pressure

56 PSI

 

(4kg/cm2)

Liquid-contacting material

PTFE/PFA

 

Liquid piping connection port Note 3

PFA 3/8" tubing

 

(N 9.53 x N 6.3)

Supply air connection port

1/4" PT

 

Max. air consumption

13.2 CFM

 

( 50 NL/min)

Ambient temperature

32-104°F

 

(0-40°C)

Note 1: The maximum discharge volume is based on pure water at 38°F (20°C).

Note 2: The self-priming value is based on the maximum stroke rate with pure water at room temperature.

Note 3: In case of threaded type, 1/8 PT female threads.

4

Page 6
Image 6