WARNINGS—Pay Attention to These Terms

DANGER:

Indicates the presence of immediate hazards which will cause severe

 

personal injury, death or substantial property damage if ignored.

 

 

WARNING:

Indicates the presence of hazards or unsafe practices which could cause

 

severe personal injury, death or substantial property damage if ignored.

 

 

CAUTION:

Indicates the presence of hazards or unsafe practices which could cause

 

minor personal injury or product or property damage if ignored.

 

 

NOTE:

Indicates special instructions on installation, operation, or maintenance which

are important but not related to personal injury hazards.

 

 

 

DANGER: Failure to install the draft hood and properly vent the water heater to the outdoors as outlined in the Venting section of this manual can result in unsafe operation of the water heater. To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper operation. Be sure to inspect the vent system for proper installation at initial start-up; and at least annually thereafter. Refer to the Maintenance section of this manual for more information regarding vent system inspections.

DANGER: Water heaters utilizing propane gas are different from natural gas models. A natural gas heater will not function safely on propane gas and vice versa. Conversion from Natural gas to propane gas (or vice versa) must be done by a qualified service technician. To avoid possible equipment damage, personal injury or fire: DO NOT connect this water heater to a fuel type not in accordance with unit data plate. Propane for propane units, Natural gas for natural gas units. These units are not certified for any other type fuel.

WARNING: Gasoline, as well as other flammable materials and liquids (adhesives, solvents, etc.), and the vapors they produce, are extremely dangerous. DO NOT handle, use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water heater. Be sure to read and follow the warning label pictured below and other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in property damage, bodily injury, or death.

WARNING: Propane appliances should not be installed below-grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or customs.

DANGER: PROPANE MODELS: Propane gas must be used with great caution.

• It is heavier than air and will collect first in lower

areas making it hard to detect at nose level.

• Make sure to look and smell for propane leaks

before attempting to light appliance. Use a soapy

solution to check all gas fittings and connections.

Bubbling at a connection indicates a leak that must

be corrected. When smelling to detect an propane

leak, be sure to sniff near the floor too.

• Gas detectors are recommended in propane appli-

cations and their installation should be in

Vapors from flammable liquids will explode and catch fire causing death or severe

burns.

Do not use or store flammable products such as gasoline solvents or adhesives in the same room or area near the water heater.

Keep flammable products:

1.far away from heater,

2.in approved containers,

3.tightly closed and

4.out of childrenʼs reach.

Water heater has a main burner and pilot flame. The pilot flame:

1.is on all the time and

2.will ignite flammable vapors.

Vapors:

1.cannot be seen,

2.are heavier than air,

3.go a long way on the floor,

4.can be carried from other room to the pilot flame by their currents.

accordance with the manufacturer's recommenda-

tions and/or local laws, rules, regulations or

customs.

• It is recommended that more than one method be

used to detect leaks in propane applications.

Installation:

are at least 18" above the

Do not install water heater

floor. This will reduce, but

where flammable products

not eliminate, the risk of

will be stored or used unless

vapors being ignited by the

the main burner and pilot flames

main burner or pilot flame.

Read and follow water heater warnings and instructions. If owners manual is missing, contact the retailer or manufacturer.

4

Page 4
Image 4
Raypak 0135A, 0195A Are important but not related to personal injury hazards, Areas making it hard to detect at nose level

0090A, 0135A, 0195A specifications

Raypak is a leading manufacturer in the pool and spa industry, known for its reliable and innovative heating solutions. Among its product line, the Raypak 0090A, 0135A, and 0195A are notable models that stand out for their efficiency, durability, and advanced technology.

The Raypak 0090A is ideal for residential pools, offering a heat output of 90,000 BTU per hour. It utilizes a copper heat exchanger, which provides efficient heat transfer and is resistant to corrosion, making it perfect for chlorinated pools. This model features a digital thermostat that enhances user control, allowing for precise temperature settings. Additionally, the 0090A is compatible with both natural gas and propane, providing flexibility depending on user preference.

The Raypak 0135A, with its 135,000 BTU output, is designed for larger residential pools or smaller commercial applications. This model employs advanced energy-efficient technology, helping to reduce operational costs while maintaining optimal heating performance. One of the key features of the 0135A is its built-in electronic ignition system, which improves reliability and eliminates the need for a standing pilot, enhancing safety and efficiency. The unit's compact design allows it to fit in tight spaces while still providing robust heating capabilities.

The Raypak 0195A is the most powerful of the trio, delivering 195,000 BTU, making it suitable for larger pool setups and high-demand environments. It also uses a copper heat exchanger, ensuring excellent heat retention and durability against corrosion. The 0195A is equipped with an easy-to-use digital display, offering intuitive controls for temperature adjustments and operational monitoring. This model also incorporates a high-tech air intake design, which maximizes airflow and reduces energy consumption.

All three models are designed for outdoor installation and possess weather-resistant features, ensuring longevity and reliability through various environmental conditions. Additionally, they are equipped with easy access service panels for maintenance, ensuring that servicing is efficient and straightforward.

In summary, Raypak's 0090A, 0135A, and 0195A models are designed to meet diverse heating needs with advanced technology, energy efficiency, and robust construction, making them excellent choices for anyone looking to enhance their pool experience.