Raypak P-926, P-1826, P-2100, P-4001 Remove the poolstat control cover by removing the two cover

Models: P926, P1826, P2100, P4001 P-926, P-1826, P-2100, P-4001 1287-1758, 2100-4001

1 38
Download 38 pages 3.29 Kb
Page 10
Image 10
1. Remove the poolstat control cover by removing the two cover

Raypak recommends the installation of an air bleed vent at a suitable location (usually the highest point) to remove air from the piping system. These units should be available at your local wholesale supplier. Raypak does not provide this item.

CAUTION:

Power to the heater should be interlocked with the main system pump to make sure the heater does not fire without the main system pump in operation.

Improper flow control can damage the heater. Uncontrolled flow (too high) or restricted flow (too low) can seriously affect heater operation. Follow these instructions to make sure your heater is properly installed.

Models 1287 through 4001 are equipped with an external pump and bypass arrangement that blends outlet water with the inlet to increase the inlet water temperature, thereby reducing the likelihood of condensation forming on the heat exchanger. The pump also serves to circulate water through the heater from the main system piping.

To complete the installation of the pool heater, the pool thermostat needs to be installed in the main return water line. This will ensure that the heater will be energized at the right time. If the main water line is too far away from the heater and the capillary bulb will not reach it, locate the pool thermostat adjacent to the main line and run wires back to the heater. Follow the instructions listed below to install the pool stat.

MOUNTING THE POOLSTAT CONTROL WITH FRONT-MOUNTED LOOP USING MOUNTING SLOTS

For heater models:

1287, 1336, 1414, 1468, 1571, 1631, 1758, 1826, 2100, 2500, 3001, 3500, 4001.

Note: For more detail on piping, see figures 9268 and 9269.

1. Remove the poolstat control cover by removing the two cover

 

screws at the top. See Figs. 1 & 2.

 

2. Lace metal strapping or clamps, (NOT PROVIDED) through the ¾”

 

slots on the cover and fasten securely to pipe as shown in Figs. 3

Fig. 1: Poolstat Control

& 4. NOTE: Do not over-tighten clamps.

 

3.Remove either the left or right “knock-out” for wiring on the poolstat control as shown in Fig. 5.

4.Attach appropriate conduit and connectors to the poolstat control.

5.Attach wires to the poolstat wire terminals. See Fig.6.

6.Install poolstat control to the cover and fasten cover screws.

7.Poolstat should be mounted level as shown in Fig. 7.

Fig. 2: Control Cover

Fig. 3: Hose Clamp Slots

Fig. 4

Fig. 5

Fig. 6

Fig. 7

10

Page 10
Image 10
Raypak P-926, P-1826, P-2100, P-4001, 1287-1758, 2100-4001 Remove the poolstat control cover by removing the two cover