SECTION 4 / SERVICING INSTRUCTIONS
GENERAL LOCATION OF CONTROLS
VIEW OF HEATER FROM FRONT | VIEW OF HEATER FROM BACK | |
| HIGH LIMITS | |
SOLID STATE |
| |
THERMOSTAT |
| |
CONTROL | UNITHERM | |
IGNITION CONTROL | ||
GOVERNOR | ||
PRESSURE SWITCH | DRAIN VALVE | |
| ||
GAS VALVE |
|
PILOT
THERMAL FUSE
Fig. # 8110.1
CONTROL PANEL REMOVAL
1.Remove lower door.
2.Remove (2) screws from bottom flange of control panel.
3.Slide down control panel to clear jacket top panel.
4.Rotate control panel down until panel stops. Do not force.
NOTE: Caution must be taken not to damage controlsor wiring.
Jacket Top Panel
CONTROLS / ADJUSTMENTS / REPLACEMENTS
TEMPERATURE CONTROLS
The pool or spa water temperature is controlled by the pool heater thermostat on the upper front panel of the heater. The control center contains an On/Off toggle switch and a thermostat. The switch functions as a means for turning the heater on or off.
The thermostat is fitted with a means of limiting the upper temperature limit below the maximum level. The knob stop adjustment ring illustrated below is adjust- able by loosening the set screw, rotating the knobstop ring to the desired location and retightening the set screw.
Control Panel |
|
| |
Typical |
|
| |
Comfortable | Typical | Comfortable | |
Spa | |||
Pool Temperature | |||
Temperature | |||
| Range | ||
Range |
| ||
|
|
Mounting Screws (2) | Knobstop Ring | Set Screw |
Fig. # 8104.0
Fig. # 8267.0 21