Raypak 155C Trouble Shooting Guide, Important Notice, Usually occurs on initial start-up

Models: 155C

1 35
Download 35 pages 10.56 Kb
Page 26
Image 26

SECTION 5 / TROUBLE SHOOTING GUIDE

IMPORTANT NOTICE

These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.

MECHANICAL (FOR QUALIFIED SERVICE PERSONNEL ONLY)

PROBLEM

Harmonics, or whining noise.

Heater going on and off continously.

Liming or scale forming on

Sooting

Pilot outage.

Yellow lazy flame

Outer jacket very hot (paint blistered)

Takes long time to heat pool or spa.

Liming

CAUSE

SOLUTION

U.G. Inoperative

Check movement by putting in hot water (110°F

 

or higher). If no movement, replace.

*Debris or restriction in system

Locate the restriction and remove. Flush system

 

and clean.

*Debris in gas line

Remove debris or blow out gas line.

Low flow

Scale forming in heat exchanger - clean heat

 

exchanger and check pool pH and total alkalinity.

Dirty filter

Backwash filter.

Low water level in pool

Raise water level.

External bypass setting out of

 

adjustment

Adjust bypass

*Pressure switch out of

 

adjustment

Adjust pressure switch

Pool water

Recommended pH should be between 7.4 and 7.8

heat exchanger.

Total alkalinity 100-150 PPM maximum. Hardness

 

150-400 PPM maximum.

High flow rates

Reduce by adding manual bypass valve and

 

adjust by putting thermometer in header (1/4"

 

NPT) drain opening. Set bypass so thermometer

 

reads between 105° and 110°F.

U.G. Inoperative

Check movement by putting in hot water (110°F

 

or higher). If no movement, replace.

*Air starvation

Refer to installation instructions.

*Improper venting

Follow recommended installation instructions.

*Insects or debris clogging

 

burner intake ports

Clean burners.

Low gas pressure

Adjust gas pressure.

Restricted pilot

Clean pilot.

Weak pilot generator

Replace pilot.

Low gas pressure

Adjust gas pressure.

*Insects or debris clogging

 

burner intake ports

Clean burners.

*Broken refractory caused by

 

shipping damage or improper

 

combustion

Replace refractory panels.

Excessive sooting of heat

 

exchanger

Determine cause of sooting & correct.

Calculate temperature in /hr

Heat rise (°/hr.)= Htr. Output

 

Pool gallonage x 8.33

 

or refer to heater sizing chart.

 

This does not take into account heat loss due

 

to weather.

Filter not running long enough

Reset time clock.

Dirty filter

Clean filter.

Gas line or meter undersized

Refer to installation instructions.

Bypassing too much water

Inspect bypass for movement, if no movement,

 

replace.

U.G. not functioning

Replace if no movement when heated.

(* Usually occurs on initial start-up.)