4. Electrical Wiring
Wireless Base
Receiver Connector
Remote Display/Keypad | “Local” Display |
Connector |
3 Temp Sensor Inputs
2 Heater Outputs
4
4 Valve Connectors | 3 |
2 | |
| 1 |
Flow Switch
Connector
8 High Voltage Relays (4 relays for
Cell Connector | Control Power | |
Input | ||
| ||
Subpanel |
|
N | L2 L1 |
Bonding Lug(s)
Ground Bus Bar
TheAqua Logic Control Center requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center. Always:
Main Service (Power to the Circuit Breaker Subpanel)
The Aqua Logic circuit breaker subpanel is rated for 100Aservice. Run properly rated conductors (L1, L2, N, and ground) from the primary house electrical panel to the main power connections on the Aqua Logic circuit breaker base. The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.