4. Electrical Wiring

4. Electrical Wiring

Wireless Base

Receiver Connector

Remote Display/Keypad

“Local” Display

Connector

3 Temp Sensor Inputs

2 Heater Outputs

4

4 Valve Connectors

3

2

 

1

Flow Switch

Connector

8 High Voltage Relays (4 relays for PS-4 unit)

Cell Connector

Control Power

Input

 

Subpanel

 

N

L2 L1

Wireless Base Bonding Lug(s)

Ground Bus Bar

TheAqua Logic Control Center requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center. Always:

-Ensure that Power is disconnected prior to doing any wiring -Follow all local and NEC (CEC if applicable) codes -Use copper conductors only

Main Service (Power to the Circuit Breaker Subpanel)

The Aqua Logic circuit breaker subpanel is rated for 100Aservice. Run properly rated conductors (L1, L2, N, and ground) from the primary house electrical panel to the main power connections on the Aqua Logic circuit breaker base. The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.

10

Page 13
Image 13