Raypak RP2100 Pool/Spa Heater
1.Turn power off to heater
2.Push the mode button to “spa” mode
3.Set the temperature to the maximum
4.Push the mode button to “OFF”
5.Lastly, plug the prewired connector in the P7 position on the board.
!IMPORTANT: The heater will display “OFF” when it is being remotely controlled by the Aqua Logic. Some homeowners see the “OFF” display and, thinking this is a mistake, change the mode to “POOL” or “SPA” which then disables the remote control by the Aqua Logic. To prevent this: Remove the heater touch pad connector (P5) which will disable the touchpad.
Black
Orange Stripe
Orange Yellow/Black Black Stripe
P7
RAYPAK RP2100
Pool/Spa |
Air |
Solar |
Heater1 |
Heater2 |
STA-RITE Heater
1.Turn power off to heater
2.Remove upper jacket and open the control box.
3.Remove the jumper for the “fireman’s switch
4.Wire to theAqua Logic using wire rated for 105°C minimum.
Fireman’s
Switch
Operating
‘Control PCB
Terminal |
Board |
STA-RITE
Pool/Spa |
Air |
Solar |
Heater1 |
Heater2 |
16 |