5. Configuration Setup
After plumbing and wiring are complete, theAqua Logic MUST BE CONFIGURED before attempting to operate. Configuration information is entered at the keypad and “tells” theAqua Logic what equipment is connected and how each should be controlled.
Accessing the Configuration Menu
Configuring theAqua Logic requires that you navigate through the Configuration Menu and input various information. For more detailed information about using theAqua Logic menu system, refer to the Opera- tion Manual.
To access the Configuration Menu
Configuration
Configuration
Menu | Press repeatedly until “Configuration Menu” is displayed | |
> | > | Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock |
> | > | Move to configuration menu items |
NOTE: The configuration menu automatically “locks” after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a “call back” to fix the configuration.
Configuration Menu Items
Each item needs to be programmed and may contain additional
Chlorinator
Enabled
+ Toggle between Chlorinator Enabled (default) and Disabled
>> Move to previous/next configuration menu item
Chlorinator
If the chlorinator is enabled (default) then the cell and flow switch must also be installed and the Aqua Logic will automatically chlorinate both the pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If disabled, then neither the cell nor flow switch need to be installed and all displays relating to the chlorinator will be suppressed.
Filter Pump Config. + to view/change
Filter Pump
1 Speed
Freeze Protect
Enabled
+Push to access pump options
> | > Move to previous/next configuration menu |
+ Toggle between
>> Move to next menu item
+ Toggle between Enabled (default) and Disabled Freeze Protection
>> Move to next menu item
Filter Pump
For
Freeze Protection
Freeze protection is used to protect the pool and plumbed equipment against freeze damage. If freeze protection is enabled and the AIR temperature sensor falls below 38°F, the Aqua
19