Generic Heaters
1.Wire heater to 120/240V power source per the instructions in the heater manual. The Aqua Logic does NOT control the power going to the heater.
2.Wire the Aqua Logic dry contact heater output per the diagram below. Many internal parts of the heater can get very
3.Set any ON/OFF switch on the heater to ON.
4.Set the thermostat(s) on the heater to the maximum (hottest) setting.
| Pool/Spa |
| Air |
| Solar |
| Heater1 |
| Heater2 |
Kill Switch | Thermostat |
| |
Heater | Ignition/Valve |
Laars Heaters (most models except LX)
1.Turn power off to heater
2.Remove factory jumper from terminal block
3.Wire Aqua Logic to the heater as shown
4.Ensure toggle switch is in the ON position
5.Set heater thermostats to maximum position
to limit switches
remove jumper
white
white
Pool/Spa |
Air |
Solar |
Heater1 |
Heater2 |
Fusible Link
14