INSTALLATION

FLUSH GLASS

FLUSH LOUVERS

1)Install the bottom glass trim onto the glass support.

2)Slide the glass into the bottom glass trim and secure with the glass clips using the 2 phillips head screws at the top.

3)Slide the top glass trim by sliding under the two spring clips.

Note: To re-install the glass, reverse the procedure.

WARNING

The use of substitute glass will

void all product warranties.

Do not operate the appliance if the glass panel(s) are removed, cracked or broken. Replacement of the glass panel(s) should be done by a qualified service person.

1)The Top Louver is held in place by Spring Clips. Push into place as shown.

2)Install the Spring Hinges on the left and right side of the bottom of the Firebox using 2 screws per hinge.

3)Place the Bottom Louver near the hinge. Flip hinge over the Bottom Louver and secure using 3 screws.

Hinge

Location

Bottom Louver

Regency® E21-3 Gas Fireplace Insert

19

Page 19
Image 19
Regency E21-LP3, E21-NG3 Flush Glass Flush Louvers, Use of substitute glass will Void all product warranties