INSTALLATION
GAS CONNECTION
Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
The gas connection is a 3/8" NPT accessible on the left side of the unit. The gas line connection may be made of rigid pipe, copper pipe or an approved flex connector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.
When using copper or flex connectors use only approved fittings.Always provide a union so that gas lines can be easily disconnected for burner or fan servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement.
Important: Always check for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing.
For minimum and maximum supply pressure see the System Data table.
1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry fireplace that has been chosen for the Regency® Gas Fireplace.
2)The appliance is provided with an opening on the left hand side of the control compartment for the gas line.
Note: During any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance and its individual
CAUTION: If the glass is removed for servicing, it must be replaced prior to operating the appliance. The glass must be fixed in the closed position when operating.
System Data
| For altitude: | Natural Gas | |||
|
| Propane: | |||
|
|
|
| ||
| Burner Inlet Orifice Sizes: |
|
| ||
|
| Natural Gas | Propane | ||
| Burner |
| #43 | #54 |
|
|
|
|
|
| |
| Max. Input Rating |
|
|
| |
| - Natural Gas | 23,500 Btu/h | |||
| - Propane |
| 22,500 Btu/h | ||
|
|
|
|
| |
| Min. Input Rating |
|
|
| |
| - Natural Gas | 11,750 Btu/h | |||
| 11,250 Btu/h | ||||
|
|
|
|
| |
| Supply Pressure |
|
|
| |
| Natural Gas |
| min. | 5.0" w.c. | |
| Propane |
| min. | 12.0" w.c. | |
|
|
|
| ||
| Manifold Pressure (High) |
|
| ||
| Natural Gas |
| 3.8" | +/- 0.2" w.c. | |
| Propane |
| 11" | +/- 0.2" w.c. | |
| Circulation Fan: 120 VAC, 60 Hz | ||||
| Variable Speed: 127 CFM, thermally | ||||
| activated |
|
|
|
|
|
|
| |||
| NATURAL GAS | ||||
| For altitude: | 2000 ft - 4500 ft. | |||
| Burner Inlet Orifice Size: | 44 DMS | |||
| Max. Input Rating | 22,000 Btu/h | |||
| Min. Input Rating | 11,000 Btu/h |
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA
Regency® | 9 |