Regency E21-LP3 Installation, Conversion Kit# 534-969from NG to LP, LPG Conversion Kit Contains

Models: E21-LP3 E21-NG3

1 36
Download 36 pages 49.42 Kb
Page 21
Image 21
Conversion Kit# 534-969 from NG to LP

INSTALLATION

Conversion Kit# 534-969 from NG to LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.

LPG Conversion Kit Contains:

Qty. Part #
Description

1

904-163

Burner Orifi ce #54

1

904-529

5/32" Allen Key

1918-590 Label "Converted to LPG"

1

908-528

Red "LPG" label

1

910-037

LP Injector (Pilot Orifi ce)

1

910-233

Thermodisc Switch

1

918-482

Instruction Sheet

DC Sparker Kit Contains:

Qty. Part #

Description

1

820-475

Bracket DC Sparker

1

820-476

Bracket DC Sparker

1

904-153

Washer #8 External Star

1

904-330

Nut 8-32 Hex

1904-531 Bushing Split Plastic

0.500 in.

6) Remove the Grate by removing the 2

10) Remove burner orifi ce with 1/2"

screws; one on each side of the grate.

wrench. Use another wrench to hold

 

onto the elbow behind the offi ce

 

Replace with the #54 orifi ce in the Kit.

Remove the 2 screws holding

Burner
Orifi ce

the grate in position.

 

7) Remove the Burner Tray by removing 111) Turn control knob to the “OFF”
screw on each side of the tray, then slideposition.
the tray to the left and lift out.

 

 

12) Remove the black protection cap by

 

hand from the high-low knob (Fig.1).

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type "B",

Black Oxide

1910-073 Spark Generator Battery Holder

1

910-074

Spark Generator Switch

 

 

C/W Wire

1

910-078

Battery Size AA

 

 

Energizer En91

1

910-199

Clip Wire Holder

1910-903 Wire Fan To Power Cord Ground 30 in.

904-781 Velcro Hook, Black

904-782 Velcro Hook, Black

Installation of LPG

Conversion Kit:

1)Turn the unit off and allow it to cool to room temperature.

2)Shut off gas supply.

3)Unplug or disconnect power source to stove.

4)Remove glass front (see Door Glass Replacement section in the manual).

5)Remove logs and brick panels (if installed).

Remove the 2 screws,push Burner Tray to the left, and lift off.

8)Pull off the pilot cap to expose the pilot orifi ce.

9)Unscrew the pilot orifi ce with the allen key (provided) and replace with the LP pilot orifi ce in the kit.

Fig. 1

13)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Fig.2

Regency® E21-3 Gas Fireplace Insert

21

Page 21
Image 21
Regency E21-LP3 Conversion Kit# 534-969from NG to LP, Installation of LPG Conversion Kit, LPG Conversion Kit Contains