Models: E21-LP3 E21-NG3

1 36
Download 36 pages 49.42 Kb
Page 23
Image 23
Heat Shield

INSTALLATION

29)Install the 1/2" bushing to the heat shield.

30)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

32)Connect the ground wire to the DC Sparker mounting bracket.

33)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

35a) Remove the bottom louver (if in place) by unscrewing the four screws located on the hinges.

35b) Location to mount the DC Sparker.

31)Plug the DC spark generator wires to the DC Sparker.

Battery

Compartment

34)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

36)Tie up the loose wire with the wire clip.

37)Check for gas leaks.

38)Check inlet and outlet pressures.

39)Check operation of fl ame control.

40)Check for proper fl ame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.

Regency® E21-3 Gas Fireplace Insert

23

Page 23
Image 23
Regency E21-LP3, E21-NG3 installation manual Installation, Installer Notice, Heat Shield, Battery Compartment