Regency I2100M Installation, Draft Control, Door Handle, Side View, Front View, Pull Open

Models: I2100M

1 20
Download 20 pages 46.52 Kb
Page 12
Image 12
Side View

INSTALLATION

A tighter fit will ensure the tube will not move when the unit is burning. See the diagram for the large air tube installation (page 11), though there are only three air tubes in the medium units.

2)Slide the left baffle brick over the air tubes from the front and then push it to the back.

Lift the rear of the baffle, pivoting it on the air tube, until it clears the rear air channel.

Side View

3) Tilt the left baffle brick up on top of the side channel and it will leave enough room to position the right baffle brick in the same manner as Step 1) above. Then reposition the left baffle brick flat on the air tube.

Slide the rear of the baffle on top of the rear air channel in front of the locating tabs. Make sure that the insulation is lying flat and does not obstruct the smoke from getting up the flue

Side View

3)Tilt the left baffle brick up on top of the side channel and it will leave enough room to position the right baffle brick in the same manner as Step 1) above. Then reposition the left baffle brick flat on the air tubes.

Front View

4)Important: push both baffle bricks so they are tight against the side walls.

Front View

4) Important: push both baffle bricks so they are tight against the side walls.

Front View

Note: When getting the chimney cleaned, remove the baffle bricks for ac- cess to the flue, then replace them when cleaning is completed.

opening. Place hold down weights on top of the insulation - one on each side.

DRAFT CONTROL

Before establishing your first fire, it is important that your fully understand the operation of you draft control. The draft rod is on the left side of the Inserts and it controls the intensity of the fire by increasing or decreasing the amount of air allowed into the firebox. To increase your draft - pull open, and to decrease - push closed.

Front View

Small Insert I1100S

1)If the two air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side until it locks into position. If the tube will not slide in easily simply use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will ensure the tube will not move when the unit is burning. See the diagram for the large air tube installation (page 11), though there are only two air tubes in the small units.

2)Slide the left baffle brick over the front air tube and then slide it back over the rear air tube.

Hearth Heater (H2100M) -

Steel Baffle

Place the insulation batt on top of the baffle. Make sure that this batt is laying flat and does not obstruct the smoke from getting up the flue opening. This insulating batt may be wrapped in paper for handling purposes and does not require removal. Batt hold down weights are supplied with the unit and are to be placed on the insulation to either side of the flame spread- er as shown in the diagram and at the rear, directly in front of the flue opening.

Lift the front end of the baffle up and over the rear of the air

tube. On Hearth Heater

(H2100M) re-

move center tube by sliding it sideways first and then down.

Pull Open

Push Closed

As well as a primary and glass wash air system, the unit has a full secondary draft system that allows air to the induction ports at the top of the firebox, just below the flue baffle.

WARNING: To build a fire in ignorance or to disregard the information contained in this section can cause serious perma- nent damage to the unit and void your warranty.

DOOR HANDLE

Attach spring handle by rotating counter clock- wise onto rod.

Ensure that the rod fits into the entire length of the

spring handle.