INSTALLATION
FRAMING & FINISHING
1)Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is
deep (1143mm x H 1219mm W x 616mm D). See Diagram 1. Also see Diagram 2 for corner installations.
IMPORTANT: Header must be metal stud.
Diagram 1
Diagram 3
2) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)
3) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base.
Diagram 2
INSTALLATION
Regency® L676E Direct Vent Gas Fireplace | 11 |