MAINTENANCE
9) Carefully remove the bottom brick panel. | 13) | Disconnect the inlet gas line from the valve. |
| 14) | Disconnect the 2 connectors from the modulating coil and the wire |
|
| harness. |
MAINTENANCE
Bottom Brick Panel
10)Loosen the 2 screws that hold the right side heat shield in place.
Heat
Shield
11)Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox).
12)Disconnect both sources of power; the power cord, located on the left hand side of the fi rebox and the wires connected to the
Wire Harness
Connectors
Wire Harness Disconnected
15)Remove the control box by carefully lifting off the velcro and sliding it out from the side of the fi rebox.
NOTE: The control box will need to be fl ipped as it is being brought out from the side of the fi rebox.
Back-up Battery shown