Regency L676E-NG, L676E-LP Installation, Venting Arrangements, Vent Restrictor Setting

Models: L676E-LP L676E-NG

1 48
Download 48 pages 51.05 Kb
Page 19
Image 19
VENT RESTRICTOR SETTING:

INSTALLATION

VENTING ARRANGEMENTS

ALLOWABLE HORIZONTAL TERMINATIONS

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o two 45o elbows equal one 90o elbow).

Note: Must use optional rigid pipe adapter (Part# 770-994) when using Rigid Pipe Venting Systems.

VENT RESTRICTOR SETTING:

NG Units; Vent restrictor at Set 0 - factory set, no adjustment required unless otherwise indicated.

LP Units; Vent restrictor at Set 1 - factory set, no adjustment required unless otherwise indicated.

Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor to Set 1, Set 2 or Set 3 if required.

A vent guard maybe required as per local codes, refer to "Exterior Vent Termination Requirements" section for details.

Note: Regency® Direct Vent System (Flex) is only approved for horizontal terminations.

Maintain clearances to combustibles as listed in "Clearances" section

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

A wall thimble is mandatory for all horizontal terminations due to high temperatures.