VALVE TRAY REPLACEMENT

MAINTENANCE

VALVE TRAY REPLACEMENT

1) Remove the exterior brick panels.

6) Remove the front burner by removing the screw.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Front Burner

Latch

b.Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up.

Hinge

Door

3)Remove the log set.

4)Remove the interior brick panels.

5)Remove the grate by undoing the 2 screws on the left and right side.

Front Burner Removed

7)Remove the back burner by removing the screw.

MAINTENANCE

Back Burner

8)Remove the rear log stand by removing the 4 screws.

Rear Log Stand