Regency L676E-LP, L676E-NG Maintenance, Back-up Battery Power Receptacle, F A C D E

Models: L676E-LP L676E-NG

1 48
Download 48 pages 51.05 Kb
Page 38
Image 38
Back-up

MAINTENANCE

4)Disconnect both sources of power; the power cord, located on the left hand side of the fi rebox and the wires connected to the back-up battery located on the right side of the fi rebox.

Back-up

F Battery

Power

Receptacle

7)Disconnect the spark cable and fl ame sensor wires from the control board.

MAINTENANCE

5)Remove the control box by carefully lifting off the velcro and sliding it out from the side of the fi rebox.

NOTE: The control box will need to be fl ipped as it is being brought out from the side of the fi rebox.

6)Disconnect the wire harnesses from the control board labelled A, C, D, E & F. Do not disconnect the the jumper cables labelled B.

F

A C D E

8)Remove the cable tie from control box to release the wires. Do not discard cable tie.

9)Remove the ground screw from the side of the control box. Do not discard the ground screw.

10)Replace the control box.

11)Re-connect wires harnesses. Ensure that the cables match the letters labelled on the control box and are securely connected.

12)Reinstall the ground screw.

13)Reverse steps 8 to 1.

38

Regency® L676E Direct Vent Gas Fireplace

Page 38
Image 38
Regency L676E-LP, L676E-NG Maintenance, Back-up Battery Power Receptacle, F A C D E, 10Replace the control box