Regency L676E-NG, L676E-LP Installation, Venting Arrangements, FPI Kit #, Length, Contains

Models: L676E-LP L676E-NG

1 48
Download 48 pages 51.05 Kb
Page 15
Image 15
VENTING ARRANGEMENTS

INSTALLATION

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency® Direct Vent System

These venting systems, in combination with the L676E, have been tested and listed as a direct vent heater system by Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.

FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the L676E using a flexible vent.

FPI Kit #

Length
Contains:

#946-618

6 Feet

1)

8” fl exible liner (Kit length)

 

 

2)

5” fl exible liner (Kit length)

 

 

3)

spring spacers (3)

 

 

4)

thimble (2)

 

 

5)

AstroCap termination cap (1)

#946-616

10 Feet

6)

screws (12)

 

 

7)

tube of Mill Pac (1)

 

 

8)

plated screws (8)

 

 

9)

S.S. screws #8 x 1-1/2” drill point, (4)

 

 

10)

vinyl siding standoff

 

 

 

 

* A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.

Notes:

1) Liner sections should be continuous without any joints or seams.

2) Only Flex pipe purchased from FPI may be used for Flex installations.

3) Horizontal vent must be supported every

3 feet.

4) A wall thimble is mandatory for all horizontal terminations due to high temperatures.

INSTALLATION

Regency® L676E Direct Vent Gas Fireplace

15

Page 15
Image 15
Regency L676E-NG, L676E-LP installation manual Installation, Venting Arrangements, FPI Kit #, Length, Contains