Regency S2100M, F2100M installation manual Minimum Clearance to Combustible Materials

Models: S2100M F2100M

1 28
Download 28 pages 37.9 Kb
Page 10
Image 10

INSTALLATION

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove.

Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.

Residential Installation “C” Vent

(Single Wall)

 

 

 

 

Unit

 

 

 

From Unit

From Corner

From Flue Center-line

 

 

 

A

 

B

C

D

E

F

Small F1100S

with

Airmate

13"

 

11"

8"

25"

17.5"

20"

 

with

Rear Deflector

15"

 

10.5"

11"

27"

17"

23"

Medium F2100M

with Airmate

14"

 

10"

6"

26"

16.5"

17.5"

 

with

Rear Deflector

17"

 

11"

9"

29"

17.5"

21"

Medium S2100M Step Stove

14"

 

10"

6"

26"

16.5"

17.5"

Large F3100L

with

Airmate

18"

 

12"

8.5"

32"

18.5"

22"

 

with

Rear Deflector

20"

 

14"

10.5"

34"

20.5"

24"

Large S3100L Step Stove

18"

 

12"

8.5"

32"

18.5"

22"

 

 

 

 

 

 

 

 

 

 

Residential Close Clearance (To be installed with required pipe components)

When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.

Unit

 

 

 

 

From Unit

 

From Corner

From Flue Center-line

 

 

 

 

 

A

 

B

C

 

D

E

F

Small F1100S

with

Airmate

9"

 

5"

3"

 

21"

11.5"

15"

 

 

with

Rear

Deflector

13.5"

 

5"

5"

 

25.5"

11.5"

17"

 

Medium F2100M

with Airmate

10"

 

4.5"

7.5"

 

22.5"

11.5"

20"

 

 

with

Rear

Deflector

14"

 

7"

8.5"

 

26.5"

14"

21"

 

Medium S2100M Step Stove

 

10"

 

4.5"

7.5"

 

22.5"

11.5"

20"

 

Large F3100L

with

Airmate

16"

 

9.5"

8.5"

 

30"

16"

22"

 

 

with

Rear

Deflector

20"

 

12"

8.5"

 

34"

18.5"

22"

 

Large S3100L Step Stove

 

16"

 

9.5"

8.5"

 

30"

16"

22"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mobile Home Close Clearance (To be installed with required pipe components)

"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)

 

 

Unit

 

 

From Unit

 

From Corner

 

From Flue Center-line

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

 

E

F

 

 

 

Small F1100S

with Airmate

11"

 

6"

6"

 

23"

 

12.5"

18"

 

 

 

with Rear

Deflector

13"

 

5"

9"

 

25"

 

11.5"

21"

 

 

 

Medium F2100M with Airmate

16"

 

8.5"

7.5"

 

28.5"

 

15.5"

20"

 

 

 

with Rear

Deflector

18"

 

8.5"

8.5"

 

30.5"

 

15.5"

21"

 

 

 

Medium S2100M Step Stove

16"

 

8.5"

7.5"

 

28.5"

 

15.5"

20"

 

 

 

Large F3100L

with Airmate

18"

 

9.5"

10"

 

32"

 

16"

23.5"

 

 

 

with Rear

Deflector

20"

 

12"

10"

 

34"

 

18.5"

23.5"

 

 

 

Large S3100L Step Stove

18"

 

9.5"

10"

 

32"

 

16"

23.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Regency Freestanding Woodstove

Page 10
Image 10
Regency S2100M, F2100M Minimum Clearance to Combustible Materials, Residential Installation C Vent Single Wall