Regency F2100M, S2100M Minimum Alcove Clearance to Combustible Materials, Floor Protection

Models: S2100M F2100M

1 28
Download 28 pages 37.9 Kb
Page 11
Image 11

INSTALLATION

Minimum Alcove Clearance to Combustible Materials

The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.

Note: Minimum alcove ceiling height - 84"

Maximum depth of alcove - 36"

 

 

 

 

 

From

 

From Flue

Min.

Min.Hearth

 

 

 

Unit

 

 

Unit

 

Center-line

Width

to Rear Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

H

I

J

K

L

 

 

Small F1100S

with

Airmate

11"

 

7"

23"

 

13.5"

46"

39"

 

 

 

with

Rear Deflector

13"

 

5"

25"

 

11.5"

50"

37"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium F2100M

with Airmate

10"

 

4.5"

22"

 

11.5"

44"

41.5"

 

 

 

with

Rear Deflector

14"

 

7"

26.5"

 

14"

52"

44"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium S2100M Step Stove

10"

 

4.5"

22"

 

11.5"

44"

41.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large F3100L

with

Airmate

16"

 

9.5"

30"

 

16"

60"

46.5"

 

 

 

with Rear Deflector

 

(not approved for Alcove)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large S3100L Step Stove

 

16"

 

9.5"

30"

 

16"

60"

46.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor Protection

A combustible floor must be protected by a non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 6" from each side and minimum 16" from the front face of the stove and minimum 6" (or the rear clearance to combustibles whichever is smaller) from the rear of the stove.

 

Minimum Overall Width (X) of Floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protector for all installations:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small Stove

F1100S

36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium Stove

F2100M

36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium Step Stove

S2100M

36"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large Stove

F3100L

40"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large Step Stove

S3100L

40"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: In Canada, floor protection must extend 18" to the front and 8" to each side of the stove.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Overall Depth (Y) of Floor Protector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Residential

 

 

 

Residential

 

Mobile Home

Alcove

 

 

 

 

Unit

 

 

 

 

 

"C" Vent

 

 

Close Clearance

 

Close Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

Z

 

 

Y

Z

 

Y

Z

Y

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small F1100S

with

Airmate

 

 

38"

 

6"

 

 

 

37"*

5"

 

 

38"

 

6"

38"

 

6"

 

 

 

 

with

Rear Deflector

 

38"

 

6"

 

 

 

37"*

5"

 

 

37"*

 

5"

37"*

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium F2100M

with Airmate

 

 

43"

 

6"

 

 

 

41.5"*

4.5"

 

43"

 

6"

41.5"*

 

4.5"

 

 

 

 

with

Rear Deflector

 

43

 

6"

 

 

 

43"

 

6"

 

 

43"

 

6"

43"

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium S2100M Step Stove

 

 

43"

 

6"

 

 

 

41.5"*

4.5"

 

43"

 

6"

41.5"*

 

4.5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large F3100L

with

Airmate

 

 

43"

 

6"

 

 

 

43"

 

6"

 

 

43"

 

6"

43"

 

6"

 

 

 

 

with

Rear Deflector

 

43"

 

6"

 

 

 

43"

 

6"

 

 

43"

 

6"

n/a

n/a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Large S3100L Step Stove

 

 

 

43"

 

6"

 

 

 

43"

 

6"

 

 

43"

 

6"

43"

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The rear clearance to combustibles is less than 6", for corner installations the rear corners may be angled to take advantage of the closer clearances.

Regency Freestanding Woodstove

11

Page 11
Image 11
Regency F2100M, S2100M installation manual Minimum Alcove Clearance to Combustible Materials, Floor Protection