INSTALLATION

TABLE 1

MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET

(Measured from the top of the unit)

 

 

 

# OF ELBOWS

 

 

 

 

ELEVATION (FT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABOVE SEA LEVEL

0

2 x 15o

4 x 15o

2 x 30o

4 x 30o

2 x 45o

4 x 45o

 

 

 

 

 

 

 

 

 

 

 

0-1000

 

12.0

13.0

14.0

15.0

18.0

16.0

20.0

 

1000-2000

 

12.5

13.5

14.5

15.5

19.0

16.5

21.0

 

2000-3000

 

13.0

14.0

15.0

16.0

19.5

17.0

21.5

 

3000-4000

 

13.5

14.5

15.5

17.0

20.0

18.0

22.5

 

4000-5000

 

14.0

15.0

16.0

17.5

21.0

18.5

23.0

 

5000-6000

 

14.5

15.5

17.0

18.0

21.5

19.0

24.0

 

6000-7000

 

15.0

16.0

17.5

18.5

22.5

20.0

25.0

 

7000-8000

 

15.5

16.5

18.0

19.0

23.0

20.5

25.5

 

8000-9000

 

16.0

17.0

18.5

20.0

24.0

21.0

26.5

 

9000-10000

 

16.5

17.5

19.0

20.5

24.5

22.0

27.0

 

 

 

 

 

 

 

 

 

 

 

NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.

RECOMMENDED

HEIGHTS FOR

WOODSTOVE FLUE

Simple rules on draft. See Table 1.

1)At sea level minimum height is 12' straight.

2)Add the following vertical height to com- pensate for:

45 deg. elbow = 1 ft.

90 deg. elbow = 2 ft.

"T"= 3 ft.

Each foot of horizontal run = 2 ft.

3)Add 4% overall for each 1000' above sea level.

Example: a)

 

 

1-1/2 ft. of horizontal run

= 3 ft.

one "T"

 

= 3 ft.

Total Addition (at sea level)

= 6 ft.

Example: b)

 

 

One 90 deg. elbow

= 2 ft.

2 ft. of horizontal run

= 4 ft.

one "T"

 

= 3 ft.

Total Addition (at sea level)

= 9 ft.

Recommended Flue Height

Elevation

Example a)

Example b)

0'

18'

21'

1000'

18.72'

21.84'

2000'

19.44'

22.68'

5000'

21.60'

25.20'

8000'

23.76'

27.72'

MOBILE HOME INSTALLATION

Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole through your floor protector and the floor directly under your pedestal base to the outside. Use 4" duct pipe with a mesh grill to pipe fresh air into the pedestal area. Block off the hole in the back of the pedestal with the square plate and the two 1/2" screws provided.

Place your unit in position and secure it to the floor using two lag bolts 3/8" x 3-1/2" through the two holes inside the pedestal base. It is important to maintain the structural integrity of the Mobile Home floor, walls and roof when installing your unit.

For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer.

14

Regency Freestanding Woodstove

Page 14
Image 14
Regency S2100M, F2100M installation manual Recommended Heights for Woodstove Flue, Mobile Home Installation