INSTALLATION

LISTED COMPONENTS

FOR MOBILE HOME

INSTALLATION

The Regency Small, Medium, Medium Step and Large Freestanding pedestal units are ap- proved for installation in a Mobile Home if one of the following pipe systems is used.

U.S. Installation*

METALBESTOS SSII

Qty. Part #

Description

1 6DS-VK

Connector Kit

SIMPSON DURA-PLUS

Qty.Part #

Description

1

6DVL8693

Connector Kit

1

6DP-MH9096 Mobile Home Kit

ICC EXCEL 2100

Qty.Part #

Description

1

6CL48

48" Chimney length (also in 12",

 

 

18", 24" lengths.

1

6RC

Rain Cap

1

6RCS

Spark Screen (for rain cap)

1

6RDS/SQS

Round/Square support box

1

6VF

Flashing

1

6UBA

"Ultrablack" Close Clearance

 

 

Connector

Large Stoves F3100L and S3100L

The unit arrives with the first two air tubes (from the front) and the 2 baffle bricks on the floor of the firebox. The baffle bricks are positioned first and then the air tubes are installed.

NOTE: If the first 2 airtubes are already installed in the stove, they must be removed in order to install the Brick Baffles.

1)Slide the left baffle brick over the two rear air tubes and then push it all the way to the left side of the firebox.

1

6TMH

Shield/Support

1

6TAF-6

Flashing

1

6T-36

Chimney Length

1

6T-18

Chimney Length

1

6T-CT

Rain Cap

PRO-JET 3103

 

Qty.Part #

Description

1

PV06-TK

Connector

1

CSB

Shield/Support

1

RRS

Radiation Shield

1

LFR03

Flashing

1

SL3

Chimney Length

1

SL1

Chimney Length

1

RCSA

Rain Cap

SECURITY ASHT

Qty.Part #

Description

1

DL42A-6

Connector Kit

1

6SS

Shield/Support

1

6FAMH

Flashing

1

6L3

Chimney Length

1

6L1

Chimney Length

1

CPE

Rain Cap

SECURITY S2100

Qty.Part #

Description

1

DL42A-6

Connector Kit

1

6XSF

Support

Canadian Installations*

SECURITY S2100 (see above for details)

ICC EXCEL 2100 (see above for details)

*The use of alternate pitch flashings, support box extensions, additional chimney lengths, and additional chimney bracing, may be used on each of the previously listed systems. These parts though must be from the same system as listed, and must be a similar and/or complimen- tary part.

CAUTION: At no time use unlabelled parts, or substitute parts made for another chimney system.

Install as per chimney manufacturer's installa- tion instructions.

BRICK FLUE BAFFLE & SECONDARY AIR TUBE INSTALLATION

Side View

2)Tilt the first Baffle Brick down and then slide the 2nd Baffle Brick up and back. Reposi- tion both baffle bricks flat on the air tubes.

1

6XFA

Flashing

1

6XL3

Chimney Length

1

6XL18

Chimney Length

1

6XCPE

Rain Cap

METAL-FAB TEMP/GUARD 2100

Qty.Part #

Description

1

6DWBK

Connector

1

6TGRS

Roof Support

1

6TGG36

Chimney Length

1

6TGG12

Chimney Length

1

6TGF

Flashing

1

6TGC

Rain Cap

AMERI-TEC HS

 

Qty.Part #

Description

1

6DCC

Connector

1

6HSRS-12

Roof Support (6PLRS-12-BK)

1

6F

Flashing

1

6HS-36

Chimney Length

1

6HS-18

Chimney Length

The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The brick baffles must be installed prior to your first fire. Smoke spillage and draft problems may occur if the baffles are improperly positioned. Check the position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox.

The Large Stoves F3100L and S3100L are shipped with two of the secondary air tubes loose inside the firebox. They need to be in- stalled after the brick baffle are installed. Follow the directions below.

3)Important: push both baffle bricks so they are tight against the side walls.

1 6HS-RCS Rain Cap (6PL-MPC)

Front View

Regency Freestanding Woodstove

15

Page 15
Image 15