INSTALLATION

CONVERSION KIT #514-969 FROM NG TO LP

for P36D-1 / P36-4 / U32-4 / U37-1 using SIT 820 NOVA Gas Valve

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!

Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.

Conversion Kit Contains:

For P36D-1 / P36-4 Only:

6) Pull off the pilot cap to expose the pilot

 

orifice.

5)Remove the 2 screws holding the Burner Assembly to the firebox base. Push the Burner Assembly to the left and lift out.

Qty.

Part #

Description

1

904-390

Burner Orifice #52

1

904-529

5/32" Allen Key

1

918-590

Decal "Converted

 

 

to LPG"

1

908-528

Red "LPG" label

1

910-037

LPG Injector

 

 

(Pilot Orifice)

1

918-481

Instruction Sheet

DC Sparker Kit Contains:

Qty.

Part #

Description

1

820-475

Bracket DC Sparker

1

820-476

Bracket DC Sparker

1

904-153

Washer #8 External Star

1

904-330

Nut 8-32 Hex

1904-438 Plug Nylon 0.750 Hole, Black

2904-531 Bushing Split Plastic

0.500 in.

1904-543 Screw 8-32 x 3/4 Pan Head

2904-553 Screw #8 x 1/2 Type "B",

Black Oxide

1

910-073

Spark Generator Battery

 

 

Holder

1910-074 Spark Generator Switch C/W Wire

1

910-078

Battery Size AA

 

 

Energizer En91

2

910-199

Clip Wire Holder

1910-903 Wire Fan To Power Cord Ground 30 in.

904-781 Velcro Hook, Black

904-782 Velcro Hook, Black

Remove the 2 screws, push Burner Assembly

to the left and lift out.

For U32-4 Only:

5a) Remove the grate by removing the screws on each side of the grate.

Remove the 2 screws

holding the grate in position.

5b) Remove the Burner Tray by removing the screws on each side of the tray. Push the tray to the left and lift up.

7)Unscrew the pilot orifice with the allen key; then replace with the LPG pilot orifice and the pilot cap, provided in the kit.

8)Remove burner orifice with a 1/2" wrench. Use another wrench to hold on to the elbow behind the orifice. Discard orifice.

Installation of LPG

Conversion Kit:

1)Shut off the gas supply.

2)Remove the louvers (and bay door if it is installed).

3)Open the flush door and remove the door.

4)Remove the logs and embers (if used).

Burner Orifi ce

Remove the 2 screws,

push Burner Tray to the left, and lift off.

14

U32-4 FPI Direct Vent Gas Insert

Page 14
Image 14
Regency U32-LP4, U32-NG4 installation manual Conversion KIT #514-969 from NG to LP, For P36D-1 / P36-4 Only