LIGHTING PROCEDURE

1)The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass panel may require cleaning.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL

HOT!

Note: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

2)Read and understand these instructions before operating this appliance.

3)Check to see that all wiring is correct and enclosed to prevent possible shock.

4)Check to ensure there are no gas leaks.

5)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

6)Verify that the fl ueing is unobstructed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit - the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a mini- mum of a 60 second wait for purging.

IMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

2)Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape.

3)Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button several times until the pilot lights.After approximately one minute, release the gas control knob. The pilot fl ame should continue to burn. If the pilot does not remain lit, repeat operation allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas knob further counterclockwise to the "ON" position.

5)Use the ON/OFF switch, wall switch, thermostat or remote control to turn on the unit.

6)Rotate the fl ame height regulator (Hi/Lo) to adjust the fl ame height higher or lower.

WARNING

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION

SHUTDOWN PROCEDURE

1)Use the ON/OFF switch, wall switch, thermostat or remote control to turn off the burner.

2)Push in the PILOT knob slightly and turn clockwise to off. Do not force.

3)Turn off all electric power to the appliance if service is to be per- formed.