MAINTENANCE
4)Disconnect gas line to stove.
5)Disconnect 3/8" NPT pipe from 90o elbow on valve.
6)Disconnect the two (2) switch wires from valve.
7)Remove two (2) orifi ce bracket screws inside fi rebox.
8)Remove thermodisc to bracket by removing three (3) phillips head M5 screws.
9)Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.
10)Loosen four (4) phillips head M5 valve mounting screws from un- derside of fi rebox. Push valve assembly forward on the teardrop slots and drop down.
11)Disconnect Piezo wire.
To remove valve from valve assembly, continue.
12)Remove two (2) thermopile wires.
13)Remove thermocouple with a 9 mm (metric) spanner.
14)Remove pilot nut with an 11 mm spanner.
15)Remove valve to orifi ce nut with a 13/16" spanner.
16)Remove inlet pipe with pipe spanner. Note orientation of 90o el- bow.
17)Remove two (2) phillips head M5 screws on each side of the valve.
18)Remove valve and remove gas out 90o brass fi tting. Note orienta- tion of fi tting.
Front Cover Screws
Front of Stove
On/Off Hi/Lo
Piezo
Ignitor
Gas Inlet |
|
|
| |
Valve |
|
|
| |
mounting screws | 240 Volts | x | ||
|
| WARNING |
| |
Placement |
|
|
| |
of Decal | Thermodisc | x | ||
“Warning | Bracket |
| ||
Thermodisc | ||||
240 Volts” |
| |||
|
|
|
Thermopile wires
Orifice assembly mounting screws
Orifice
Thermocouple wire
Gas Outlet
Thermocouple nut
VIEW FROM BOTTOM OF THE STOVE
INSTALLING VALVE ASSEMBLY
1)To install a new valve assembly, reverse instructions for removing valve. See assembly steps
2) Check for leaks and manifold pressure. See Gas Pressure Test instruc- tions.
3) To reinstall valve, reverse instructions for removing valve assembly, steps
18 | Regency® |