MAINTENANCE
FAN REPLACEMENT
For Leg Unit: Remove 7 screws, remove bottom access panel and replace fan assembly.
1) Disconnect power to fan.
2) Open pedestal door and remove door cover plate by removing 4 screws. See diagram 1.
Diagram 1
3)Remove valve cover plate by removing 2 screws.
4)Disconnect the molex plug (from inside the stove).
Note: The #8 ground lug is a dedicated ground for mobile home use only.
5)Loosen the four
Wiring Diagram
Diagram 2: Ground Lug
6)Disconnect the 2 ground wires (green and yellow/green striped) to the ground lug as per diagram 2.
Note: The #8 ground lug is a dedicated ground for mobile home use only.
Diagram 3
View from back of stove
| Placement of Decal |
Strain relief | “Warning 240 Volts |
grommet | Turn Off Power” |
Regency® | 19 |