Image 5
INSTALLATION

INSTALLATION

BEFORE YOU START

INSTALLATION AND REPAIR SHOULD BE DONE BY AN AU- THORISED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORISED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERA- TIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUETOHIGHTEMPERATURES,THEAPPLIANCESHOULDBE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE COR- RECTLY MAY CAUSE A SERIOUS HOUSE FIRE AND WILL VOID YOUR WARRANTY.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDSOFHIGHSURFACETEMPERATURES,ESPECIALLY THE FIREPLACE GLASS,AND SHOULD STAYAWAYTOAVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLI- ANCE.

CLOTHINGOROTHERFLAMMABLEMATERIALSHOULDNOT BE PLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with AS5601-2004 or NZS 5261

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, AS 3100

3)See general construction and assembly instructions.

4)This appliance must be connected to a fl ue and terminate to the outside of the building envelope. Never fl ue to another room or inside a building.

5)Inspect the fl ue system annually for blockage and any signs of deterioration.

6)Any safety glass removed for servicing must be replaced prior to operating the appliance.

7)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace.

8)Wear gloves and safety glasses for protection while doing required maintenance.

9)Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

10)Installation and any repairs to this appliance should be done by an authorised service person. An authorised service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

11)Do not strike the glass door.

12)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

13)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

IMPORTANT

SAVE THESE INSTRUCTIONS

The F33-3 Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual

rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.

INSTALLATION CHECKLIST

1)Locate your appliance. Refer to the "Clearance to Combustibles" section.

2)Assemble stove base. Refer to the "Pedestal Assembly" or "Leg and Bottom Shield Assembly" sections.

3)Install fl ueing. Refer to the "Flueing" section.

4)Make gas and electrical connections. Refer to the "Gas Connec- tion" section.

Test the pilot. Must be as per diagram in the "Pilot Adjustment" section.

5)Test gas pressure. Refer to the "Gas Pipe Pressure Testing" section.

6)Test for fl ue spillage. Refer to the "Test for Flue Spillage" section.

7)Install logs and embers and rockwool where indicated in the "Log and Ember Installation" section

8)Install optional features. Refer to the following sections where applicable.

a.Optional Remote Wall Switch

b.Optional Remote Control Installation

c.Optioanl Wall Thermostat Installation

9)Final check. Refer to the "Final Check" section.

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

Regency® F33-3 Freestanding Gas Stove