5.13.4 Setting Function Profile Measurement Ranges
Choose Set Ranges from the context menu that is displayed when you right-click in the present window.
The Realtime Profile Setting dialog box will be displayed. In this dialog box, set a profile measurement range.
[Function mode]
Figure 5.131 Realtime Profile Setting dialog box
(1) Memory allocation
Before function profiles can be measured, profile memory must be allocated to the addresses at which to be measured. Profile
data can be obtained from only the address range that has had memory allocated.
The emulator permits any of 1–8 blocks (maximum 1 Mbyte) each beginning with the 128-Kbyte boundary to be specified as a
profile measurement area.
Contiguous blocks or noncontiguous blocks, either one, can be set.
With initial settings, the profile memory is allocated to addresses in the ROM and RAM areas.
(2) Automatic function detection
When profile memory is allocated to addresses, the E100 emulator automatically detects functions included that address range
and registers those functions in the window.