R0E530640MCU00 User’s Manual 5. Debugging Functions
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 201 of 229
(2) From the Trace conditions dialog box
1. In the Trace Mode drop-down list of the Trace sheet, select Fill around TP. Select the Exception check box and then click
the Detail button.
Figure 5.143 Trace conditions dialog box
2. The Exception page shown below will appear. Click the Detail button to the right of the Violation of access protection check
box.
Figure 5.144 Trace conditions dialog box