RIDGID 122XL manual Cleaning/Deburring O.D. of Tube, Turn ON/OFF switch to the OFF position

Models: 122XL

1 39
Download 39 pages 6.39 Kb
Page 9
Image 9

122XL Copper Cutting and Prep Machine

NOTE! To adjust the height of the cutter wheel, push handle to the right and relocate position pin by moving handle up or down.

6.Lower the handle until the cutter wheel support rollers contact the tubing (Figure 4). Turn the ON/OFF switch to the ON position.

CAUTION Tubing will rotate. Keep hands away from ends of tubing that may have burrs or sharp edges.

Figure 4 – Cutter Wheel Support Rollers Contacting Tubing

7.Apply pressure to the handle slowly and continu- ously until the tubing is cut. Do not force the cutter wheel into the workpiece. This will damage and short- en the life of the cutter wheel.

8.Release pressure from the handle but still have the cutter wheel support rollers maintain contact with the tubing (Figure 5). The rollers will hold the tubing so it will not fall to the ground.

9.Turn the ON/OFF switch to the OFF position.

10.Remove tubing from the machine. Raise the cutter handle to its maximum height.

Cleaning/Deburring O.D. of Tube

1.Turn the ON/OFF switch to the ON position.

2.Place the end of the tube on the rest plate. Lengths of tubing longer than four feet should be supported by pipe stands.

WARNING Pipe supports are needed to maintain control of the workpiece.

3.Press tube gently against the brush and rotate slow- ly until surface is bright (Figure 6).

WARNING Keep hands away from rotating parts.

4.Remove external burrs by rotating tube against debur- ring cutter (Figure 7). This action also bevels the end of tube for easier insertion into the fitting.

Figure 6 – Cleaning O.D. of Tube

 

 

Figure 7 – Deburring O.D. of Tube

 

Figure 5 – Cutter Wheel Support Rollers Holding Tubing

5. Turn ON/OFF switch to the OFF position.

 

After Cut

 

 

 

 

 

 

 

 

 