!WARNING:
Release all pressure and disconnect power before making any repair.1.Check compressor for any visible problems, especially check air filter to be sure it is clean.
2.Pull ring on safety valve and allow it to snap back to normal position.
!WARNING:
Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.
3.Drain moisture from tank daily. Shut compressor off. Depressurize system prior to draining tank. Drain moisture from tank by opening the tank drain valve underneath the tank.
Tank
Drain
Valve
4.Turn power OFF and clean dust and dirt from motor, tank, air lines and pump cooling fins.
NOTE: The air filter located in the filter slot in the pump head must be checked and cleaned periodically, more often if used under very dusty conditions or when a great deal of fog from spraying is allowed to circulate near unit.
IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent
!DANGER:
Never attempt to repair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explo- sion. Always replace worn, cracked or damaged tanks.
NOTICE:
Drain liquid from tank daily.The tank should be carefully inspected at a minimum of once a year. Look for cracks forming near the welds. If a crack is detected, remove pressure from tank immediately and replace.
14