Using High Temperature Display Controllers.

TEMPERATURE CONTROLS - OPERATING

Using High Temperature Display Controllers.

You will need to program the Master controller if you want to display and use temperatures over 500C. Programming only needs to be done on Master universal controllers; other universal controllers will not allow this, and Deluxe Kitchen Controllers are supplied already programmed to allow high temperatures. Temperatures in bathrooms should never exceed 500C.

STEP 1: On the Master controller press and hold the Transfer and On/Off buttons simultaneously (see fig 2.) until a “beep” is heard (approx. 5 seconds)

STEP 2: When the Master controller is switched on it should be possible to select temperatures higher than 50ºC. If not repeat STEP 1.

Note:

If the master controller is replaced, repeat STEP 1 above for the new controller.